1. Clinical Summary
Series Phase Coverage CT Lower Extremity Contrast (N/A or 60s if contrast delay) Proximal to injury to Distal to injury - Lower extremity fracture
- Tibia/fibula
- Femur
- Post-operative hardware assessment
-
2. Patient Prep
- Position: Supine
- NPO Status: N/A
-
3. IV Contrast & Injection
Parameter Value Agent None typically. Contrast if infection Volume If contrast: 100 mL Flow Rate 2-3 mL/s Use full dose if GFR > 30
If GFR < 30
Max Contrast = \(2*\left[\frac{\text{Patient Weight}}{75 \text{ kg}} * \text{eGFR}\right]\)
-
4. Special Notes
- FOV based on region: hip to ankle. Submillimeter for fracture. Extended coverage for alignment
- Additional Recons: Alignment measurements. Hardware position. 3D for surgical planning
- No IV unless contrast needed
Safety First
- Renal Function: N/A or eGFR > 30
- Allergy: N/A or check allergy
- Fractures. Alignment. Comminution. Intra-articular extension. Hardware position. Infection on contrast
- Extended coverage for alignment measurements
| Series Name | Start Location | End Location | Delay | Slice Thickness | Notes |
|---|---|---|---|---|---|
| Scout | Region specific | Extended | N/A | N/A | AP and lateral |
| CT Lower Extremity | Proximal to injury | Distal to injury | N/A or 60s if contrast | 0.625-1 mm | Submillimeter |
| Plane | Acquisition | FOV | Thickness/Increment | Kernel | IR Strength | Notes |
|---|---|---|---|---|---|---|
| Axial | Lower extremity | Region | 2 mm/2 mm | Bone | N/A | Bone windows |
| Coronal | Lower extremity | Region | 2 mm/2 mm | Bone | N/A | Coronal |
| Sagittal | Lower extremity | Region | 2 mm/2 mm | Bone | N/A | Sagittal |
| 3D surface | Lower extremity | Bones | 0.625 mm source | Bone | N/A | 3D reconstruction |